Measure the gripping surface
Nominal pipe size and outside diameter are different inputs. Record the actual connection dimensions rather than converting a nominal inch label into a presumed clamping diameter.
Read the overlap
For example, a 100 mm gripping diameter lies within the published 58–115 mm range of 20ET and 90–142 mm range of 25ET. Compare 8.0 kg versus 9.5 kg and 30 versus 18 r/min before discussing fit.
Check the edges
At 200 mm, only 50ET in this series includes that diameter in its 158–220 mm range. That still leaves material, geometry and access to confirm.